Chat with us, powered by LiveChat
We rebranded from Bioevopeak to Infitek!

Laser Particle Size Analyzer, Professional PSA-2L2309A

  1. Unique Separated Modules for Wet and Dry Dispersion
  2. Convergent-light Fourier transform optical path technology
  3. Automatic Optical Path Alignment System
  4. Automatic Sample Dispersion System
  5. Audit trail is optional to comply with 21 CFR Part 11

Share the product

Description

PSA-2L2309A is an intelligent fully automatic laser particle size analyzer that adopts the internationally advanced Mie Scattering and Fraunhofer Diffraction principle. As an integrated model with wet and dry dispersion systems, it features a high-sensitivity and high-resolution photoelectric probe system paired with an imported Canon lens optical path—these components ensure excellent accuracy and repeatability in particle size distribution measurements. The analyzer is widely used in quality control departments of industrial production and research institutions.

Features

Unique Separated Modules for Wet and Dry Dispersion

The instrument employs a modular design for automatic dry and wet dispersion. Users can freely assemble the modules according to the testing requirements of sample characteristics, making the operation simple, convenient, and efficient.

Flexible Operation Modes

Both an intelligent fully automatic operation system and a manual operation mode are available for free selection. The automatic mode is extremely easy to learn and supports SOP operation, streamlining the testing workflow.

Advanced Optical Path Design

Adopting inverse Fourier (folded optical path) technology, the reception of scattered light from sample particles is not limited by the focal length of the optical path. The test angle range spans 0.015° to 145°, effectively expanding the measurement range and improving the instrument’s resolution. The sealed optical path also delivers excellent dustproof performance.

Optical Path PSA-2L2309A

Automatic Optical Path Alignment System

Composed of precision four-phase hybrid stepper motors with a micro-stepping precision of micron level, this system maintains the optical path in an optimal state at all times, ensuring accurate and stable test results. It eliminates the need for manual optical path adjustment, reducing human intervention errors.

Automatic Sample Dispersion System

The modular design of the wet and dry dispersion systems shortens the circulation pipeline, preventing the sedimentation of large particles. This design not only facilitates uniform sample dispersion but also lowers maintenance costs and simplifies equipment cleaning and upkeep.

High-Performance Instrument Software

The proprietary unconstrained free fitting technology collects scattering data in real time during the measurement process and can automatically analyze multi-modal particle groups without being restricted by fixed functional models. Analysis results depend entirely on the distribution of the scattering spectrum, maximizing fitting accuracy and truly reflecting the particle size distribution of samples. For particles below 2 μm, the analyzer performs testing across 12 particle size grades with ultra-high physical resolution.

Software

The original unconstrained free-fitting technology collects scattering data during the measurement process. It frees particle analysis from the constraints of fixed functional models, truly reflecting the particle size distribution.

Item Function
Analysis Modes Free Distribution, R-R Distribution, Log-Normal Distribution, Mesh Size Classification, etc., meet the diverse particle size statistical requirements of different industries.
Statistical Methods Volume Distribution, Quantity Distribution
Statistical Comparison It can conduct comparative analysis on multiple test results. By comparing test results of different batches of samples, samples before and after processing, and samples tested at different times, differences can be identified. This is of great practical significance for quality control of industrial raw materials.
User-defined Analysiss Calculate the percentage based on particle size.

Calculate the particle size based on the percentage.

Calculate the percentage based on the particle size range.

These functions meet the representativeness requirements of particle testing across various industries.

Test Report

PSA-2L2309A Testing Report

Specification

Model PSA-2L2309A
Instrument type Wet and Dry
Specification
Measuring range Wet: 0.01μm to 3500μm
Dry: 0.1μm to 3000μm
Photodetector Wet: 116
Dry: 116
Accuracy Wet: ≤0.5% (CRM D50)
Dry: ≤1% (CRM D50)
Repeatability Wet: ≤0.5% (CRM D50)
Dry: ≤1% (CRM D50)
Design principle Laser Diffraction
Analysis principle Mie Scattering
Fraunhofer Diffraction
Standard ISO 13320
Audit trail Optional FDA software
Engineering
Laser Fiber Laser, 639nm, Max. 4mW
Laser safety Class 1
Detector Log-spaced array, 0.015° to 145°
Operation mode Full Automatic
Manual Control
Optical alignment Full Automatic
Test speed Wet: ≤2min
Dry: ≤1min
Typical testing time: ≤10s
Inverval time per test result: 500ms
Wet dispersion
Ultrasonic Frequency: 40kHz
Power: 60W
Time: adjustable
Stirrer Speed: 0rpm to 3000rpm adjustable
Circulate Rated Flow: 1-8L/min
Rated Power: 120W
Sample tank Volume: 600mL
Micro-sample cuvette Optional
Dry dispersion
Dry dispersion Dry-turbulence dispersion patent, normal shock wave shear technique
Sample feeding Automatic Sampler (SOP setting)
Dispersion medium Compressed Air
Technical data
Connect PC, LIMS Yes
Test Report Word, Excel, Image, Text, etc.
Working environment Temperature: 5℃ to 35℃
Humidity: <85%
Storage environment Temperature: -20℃ to 50℃
Power supply 220V, 50/60Hz
Product dimensions (L×W×H) 870mm×370mm×330mm
420mm×350mm×380mm

260mm×290mm×140mm

Net weight 32kg
15kg

7kg

    Obtenez des devis maintenant !

    Nous vous contacterons généralement dans les 24 heures. Vous pouvez également nous appeler (+86-531-88982330) pendant les heures ouvrables (de 8h30 à 17h45 UTC+8 du lundi au samedi) ou utiliser le chat en direct du site Web pour obtenir une réponse rapide.

    Contact Info

    Rm. 2014, Bldg. 3, Ligaoguojihuayuan, No. 1222, West Aoti Road, Lixia District, Jinan, Shandong

    Phone: +86-531-88982330

    Fax: +86-531-88983691

    Web: www.infitek.com

    Go to Top